catalog listings | awm92100v | awm92200v |
flow range (full scale) | +/- 200 sccm | |
pressure range | | +/- 2.0 h2o (5 mbar) |
null voltage shift, typ. | | |
-25°c to 25°c [-13ºf to 77ºf] | +/- 2.0 mv (1) | +/- 2.0 mv (1) |
25°c to 85°c [77ºf to 185ºf] | +/- 2.0 mv (1) | +/- 2.0 mv (1) |
output voltage shift, typ. | | |
-25°c to 25°c [-13ºf to 77ºf] | -3.0% fso (2) | 25% reading |
25°c to 85°c [77ºf to 185ºf] | +/-1% fso (2) | -30% reading |
1. assumes low tcr bridge resistance used (pins 2 and 8) |
2. requires recommended rc value of 1k ohm is used (pins 3 to 7) and typ. heater control circuit. maximum current rh. |
|
specifications | min. | typ. max. |
excitation (1) | 8.0 vdc | 10 ±0.01 vdc 15.0vdc |
power consumption | | 50 mw |
calibration gas | air | |
ratiometricity error (1) | ± 0.30 typ. % reading | |
repeatability and hysteresis (2) | ± 0.35% reading | |
response time | 1 ms typ. | |
pressure dr-op @ full scale (200 sccm) | 0.49 typ. mbar | |
overpressure | 25 psi max. | |
operating temperature range | -25°c to 85°c[-13°f to 185°f] | |
storage temperature range | -40°c to 90°c[-40°f to 194°f] | |
vibration | 20g’s, 10hz to 2000hz | |
shock | 100 g, 6 ms | |
weight | 5.6 grams | |
1. output voltage is ratiometric to supply voltage. |
2. repeatability and hysteresis tolerances reflect inherent inaccuracies of the measurement equipment. |