Cat No.eia05512h        
Human cyclooxygenase-2(COX-2) ELISA Kit
Dear customers, thank you for choosing our products. This product is suitable for in vitro qualitative detection of Human serum, plasma or cell culture supernatant and organizations in the natural and recombinant COX-2 concentration. Detection of other special sample please contact our technical support. The kit is for research use only. Please read the instructions carefully before using and check the kit components. If you have any questions, please contact SANCHEZ INC You will get our full range of services.
 
This kit employs Double Antibody Sandwich Technique. The principle of Double Antibody Sandwich is based on characteristics of the tested antigen with more than two valances which can identify coated antibody and detection antibody at same time. The specific process is as follows:
 
1. Connect the specific antibodies and solid phase carriers to form immobilized antibodies. Wash out uncombined antibodies and impurities. Seal the rest binding sites with irrelevant proteins.
2. Join under test with immobilized antibodies for contact reaction. After a while, combine antigens in and antibodies on carriers into the antigens complex. Wash out uncombined antibodies and impurities.
3. Add biotin labeling antibodies to combine with the antigens on immune complexes. Wash out the uncombined biotin labeling antibodies thoroughly. The enzyme amount on the carrier is now positively related to the amount of the tested substance in specimens.
4. Add horseradish peroxidase to label the avidins and incorporate them with the biotin labeling antibodies. Wash out the incorporated enzyme markers thoroughly. The enzyme amount on the carrier is now positively related to the amount of the tested substance in specimens.
5. Add substrates for coloring, and compute the concentration of specimens.
Note: an antibody molecule can be marked on several biotin molecules and a biotin molecule can be connected with a HRP-Avidin to form numbers of horseradish peroxidases combining with antibodies which shows higher sensitivity and amplification effect comparing with traditional direct HRP-Antibodies.
 
Detection principle of Human cyclooxygenase-2(COX-2) ELISA kit
This experiment use double-sandwich elisa technique and the ELISA Kit provided is typical. The pre-coated antibody is Human COX-2 monoclonal antibody and the detecting antibody is polyclonal antibody with biotin labeled. Samples and biotin labeling antibody are added into ELISA plate wells and washed out with PBS or TBS. Then Avidin-peroxidase conjugates are added to ELISA wells in order; Use TMB substrate for coloring after reactant thoroughly washed out by PBS or TBS. TMB turns into blue in peroxidase catalytic and finally turns into yellow under the action of acid. The color depth and the testing factors in samples are positively correlated.
Kit composition
name                    96 Tests  48 TestsStorage
1antibody precoated plate    8×12      8×64/-20℃
2Human COX-2 Standards   2 vial      1 vial4/-20℃
3Biotinylated antibody(1:100)    1 vial     1 vial4/-20℃
4Enzyme conjugate(1:100) 1vial      1 vial4/-20℃
5Enzyme diluent                1vial  1vial        4/-20℃
6antibody diluent               1vial  1 vial4/-20℃
7Standard diluent               1vial 1 vial      4/-20℃
8Sample diluent                1vial  1 vial   4/-20℃
9Washing buffer (1:25)         1 vial 1 vial    4/-20℃
10Colour Reagent A  1 vial 1 vial   4/-20℃
11Colour Reagent B1 vial 1 vial   4/-20℃
12Colour Reagent C  1 vial 1 vial   4/-20℃
13Instruction    1 set 1 set   RT
Note
RTRoom temperature
StandardFrozen dried
Colour Reagent A: Avoid light
 
Necessary for testing their own test facilities and equipment
1. Microplate reader (450nm detection wavelength filter, 570nm or 630nm correction wavelength filters).
2. Washer (adjustable amount of liquid injection to ensure that each well 350μl lotion without overflow).
3. Clean benches, biological safety cabinets, fume hoods.
4. High-precision single-channel dispenser (range 0.5-10μl-20μl, 20-200μl, 200-1000μl).
5. High-precision multi-channel plus liquid (8 or 12, the range of 50-300μl of).
6. 37℃ incubator.
7. Low temperature centrifuge.
8. Refrigerators (4℃, -20℃, -86℃).
9. Analytical balance.
10. Scissors, tweezers, pliers, and so on.
11. Swirl mixing device, low-frequency oscillator, and so on.
 
Necessary for testing their own testing supplies and reagents
1. Centrifuge tube (capacity of 1.5ml, 5ml, and so on).
2. Disposable tip (range of 0.5-10μl-20μl, 20-200μl, 200-1000μl).
3. Pure water or distilled water.
4. Coordinate paper.
5. Absorbent paper.
6. EDTA, sodium citrate, heparin
 
Sample collection Note
1. The tube for blood collection should be free of pyrogen and endotoxin
2. Hemolysis and hyperlipidemia specimens can not be used to extracted serum and plasma.
3.  The samples should appear clear and transparent. And all the suspension should be removed through centrifugation.
4.  If collected samples are not timely detected, they should be divided according to single usage amount and frozen reserved in refrigerator at -20-80℃, avoiding the repeated freeze-thaw.
5.  According to the actual situation of the samples, make proper multiple dilutions (Pre-experiment is strongly recommended in order to confirm the dilution ratio)
6.  Collect specimens and try to gain double dosage to avoid specimens shortage for repeated assays in case that failure in one-assay delays experimental process.
7.  Do protective measures when collecting specimens (e.g. wearing gloves, respirator, respirator, etc.), aware of the potential risk in all specimens.
8.  Specimen processing should be inside the biological safety cabinet. Ensure proper use of the biological safety cabinet.
 
Measures for the samples
1.   Serum: Put the collected whole blood in refrigerator at 4℃ for the night. Then centrifuge it for 10min at 1000-3000rpm. Take supernatant tested immediately or put samples at -20℃( for 1-3 months) or -80℃ (for 1-3 months) for storage.
2.   Plasma: Take EDTA, sodium citrate and heparin as anticoagulant. Add the plasma and mix them well. Centrifuge mixture for 10min at 1000-3000rpm. Take supernatant tested immediately or put samples at -20℃( for 1-3 months) or -80℃ (for 1-3 months) for storage.
3. Tissue homogenate: Take tissue slices and wash them out in 0.01MPBS; Add tissue protein extraction reagent according to proportion of 1G: 5-10ml and mix them in ice water. After being blended, mixture shall be centrifuged for 10min at 5000-10000rpm.Take supernatant tested immediately or put them at -20℃( for 1-3 months) or -80℃ (for 1-3 months) for storage.
4.  Cell culture: Take centrifugation for 10min at 1000-3000rpm.Take supernatant tested immediately or put samples at -20℃( for 1-3 months) or -80℃ (for 1-3 months) for storage.
5. For urine, ascites, cerebrospinal fluid, etc: ake centrifugation for 10min at 1000-3000rpm. Take supernatant tested immediately or put samples at -20℃( for 1-3 months) or -80℃ (for 1-3 months) for storage.
Note: The general principles of the sample dilution
The user should refer to the references to know the probable content of the samples before decide to dilute the samples,and the diluted content of the sample must be in the best detection range of the given ELISA Kits. The dilution of the sample should be recorded in detail.
 
Note 
1.  The kit should be kept at 2-8℃ before being used. Except the redissolved standard samples, other Ingredients must not be frozen.
2. For the concentrated biotinylated Human COX-2 antibody, the concentrated enzyme-conjugates have small size. Bumping or potential inversion of the tubes during transportation may cause the liquid sticking to wall or cap. Thus, the tubes should be shaken manually or centrifuged for 1 min at 1000rpm to shake off the adherent liquid down to the tube bottom.
3.  Concentrated washing buffer may crystallize a little. Use water bath to help the dissolution during diluting process. The crystals must be totally dissolved when preparing washing buffer.
4. During testing process, the Human COX-2 lyophilized standard sample shall be single-use and must not be divided. The sample will quickly inactivate after being dissolved because of its lower concentration.
5. Operation should be strictly in accordance with the instructions. Mixed usage of components with different batch number in this reagent is not allowed
6.  Ensure the reagent well mixed by t