产品展示
优质供应
详细内容
| |||||||||||||||||||
|
User-friendly design ? Small size & light weight ? Compact design with high performance ? Select your optimum chamber from a full variation - The series provide three variations in temperature (& humidity) range of -20 to 150℃, 0 to 120℃, -20 to 120℃/ upmost 30 to 95% RH, and three capacities of 20L, 65L, and 100L, with a total 9 models altogether ? Efficient system with durable materials - The evaporating system for better thermal efficiency with corrosion-resistant materials - The heating system with minimized potential heat when heating or cooling for prompt reaction time and advanced performance ? Water tank for easy water supply - Maintenance can be done easily from the front side ? Inner glass window for observation - A tempered window provides a clear view of your specimen during testing ? Access port for running in wires - Basic hole of 50mm diameter cable port is standard on the left side of chambers for wiring to the specimen. We also provide additional 50 or 80mm diameter cable port (Optional) ? Optional stand for space-saving layout - For use in limited space, we provided stand with casters for staking up two chambers * Be sure to secure the stand onto floor with earthquake resistant fitting for your safety when using stand. Control operation ? Microprocess PID control/ Auto-tuning/ Calibration ? Digital LCD display with touch-sensitive 7 keypads ? Easy operation with wide LCD screen - Temperature & humidity/ timer settings and operating condition ? The program patterns are memorized for 10 years even though the main power switch off, thanks to a PCB built-in battery ? Expanded parameters input - Performance by convenient letters ? Programming operation | |||||||||||||
| |||||||||||||
? Computer interface (optional) - Available to save all data in Excel - Provide a software - The program information, setting values backup/ recovery, and temperature/ humidity values storage ? Recorder (optional) - 6-point dots type recorder with digital display Safety functions ? Leakage breaker for power supply ? Over current protector ? Overheat/ overcool protectors ? Switch-off after alarm for over heating ? Water empty (TH-ME/ TH-PE only) ? Door opening alarm |
Model | TH-ME-025 | TH-ME-065 | TH-ME-100 | |
Chamber volume(L/cu ft) | 25 / 0.9 | 65 / 2.3 | 100 / 3.53 | |
Control system | BDBC2 system - Balanced Dehumidifying & Bath Cooling Control | |||
Controller | Program controller (LCD type) | |||
Temperature | Range(℃/℉) | -20 to 150 / -4 to 302 - without humidity | ||
Fluctuation1)(±℃/℉) at 25℃ / 60%RH | 0.2 / 0.36 | 0.3 / 0.55 | 0.2 / 0.36 | |
Variation1)(±℃/℉) at 25℃ / 60%RH | 0.3 / 0.55 | 0.3 / 0.55 | 0.3 / 0.55 | |
Time | Heating-without humidity(Min.) | 55 From -15℃ to 120℃ (5℉ to 248℉) | ||
Cooling-without humidity(Min.) | 60 From 20℃ to -15℃ (68℉ to 5℉) on single point control * | |||
Humidity | Range(%RH) | 55 to 95 at 15℃ (59℉) | ||
40 to 95 at 30℃ (86℉) | ||||
30 to 95 at 70℃ (158℉) | ||||
30 to 95 at 70 to 85℃ (158℉ to 185℉) | ||||
Fluctuation1)(±%RH) at 60%RH / 55℃ | 1.6 | 0.4 | 0.5 | |
Variation1)(±%RH) at 60%RH / 55℃ | 3 | 3 | 3 | |
Refrigeration | System | Mechanical single stage refrigerator system (air-cooled condenser) | ||
Refrigerant | R-404A | |||
Capacity(W) | 250 | 250 | 375 | |
Cooler | Plate fin cooler (copper) | |||
Heater | Material | Ni-Cr Wire Heater / SUS sheath Heater | ||
Drying bulb(W) | 800 | 1000 | 1000 | |
Humidity bulb(W) | 800 | 1000 | 1000 | |
Sensor | Temperature | Pt 100 | ||
Humidity | Electronic sensor - Free of drying a wet pack and good reaction time | |||
Materal | Interior | Stainless steel #304 | ||
Exterior | Steel, 1.0mm (0.04”)/ Double painted & baked | |||
Insulation | Polyurethane foam 50mm (1.97”) | |||
Door | Glass wool | |||
Air flow | Sirocco fan (60W) | |||
Water tank | Capacity(L/cu ft) | 5 / 0.18 | 6 / 0.21 | 9 / 0.32 |
Water quality | pH6.2 to 7.2/ Electrical conductivity 20?/cm to below | |||
Dimensions (WxDxH) | Interior(mm/inch) | 350x220x350 / 13.8x8.7x13.8 | 400x330x495 / 15.7x13.0x19.5 | 500x380x530 / 19.7x15.0x20.9 |
Exterior(mm/inch) | 500x760x850 / 19.7x29.9x33.5 | 550x890x1000 / 21.7x35.0x39.4 | 650x1000x1030 / 25.6x39.4x40.6 | |
Net weight(kg/lbs) | 80 ±5 / 176.0 ± 11.0 | 110 ±5 / 242.0 ± 11.0 | 130 ±5 / 286.0 ±11.0 | |
Cable access hole | Basically one hole provided/ ? 50mm (2.0") Optionally max. two holes available/ ? 50 or 80mm (2.0 or 3.2") | |||
Electrical Requirements (220V) | 60Hz/ 1ph/ 12.3A | 60Hz/ 1ph/ 13.2A | 60Hz/ 1ph/ 14.4A | |
Cat. No. | AAH82111 | AAH82121 | AAH82131 | |
Electrical Requirements (230V) | 50Hz/ 1ph/ 11.9A | 50Hz/ 1ph/ 12.7A | 50Hz/ 1ph/ 13.8A | |
Cat. No. | AAH82112 | AAH82122 | AAH82132 |
* 80mm cable access hole is NOT available for 25L chamber. (TH-ME-025)
* Above the dimension are NOT included size of attached accessories.
※ Permissible Environmental Condition: Temperature 18 to 30℃ (64.4 to 86℉), Maximum relative humidity 85%
|
* 80mm cable access hole is NOT available for 25L chamber. (TH-PE-025)
* Above the dimension are NOT included size of attached accessories.
※ Permissible Environmental Condition: Temperature 18 to 30℃ (64.4 to 86℉), Maximum relative humidity 85%
|
* 80mm cable access hole is NOT available for 25L chamber. (TC-ME-025)
* Above the dimension are NOT included size of attached accessories.
※ Permissible Environmental Condition: Temperature 18 to 30℃ (64.4 to 86℉), Maximum relative humidity 85%
| ||
| ||
| ||
| ||
| ||
|