产品展示
陶瓷砖平整度、直角度、边直度综合测定仪使用说明
点击次数:195发布时间:2022/6/17 11:53:39
更新日期:2024/11/14 15:54:14
所 在 地:中国大陆
产品型号:HBTCY-02型
优质供应
详细内容
本公司6月17号09点19分报道: HBTCY-02型陶瓷砖平整度、直角度、边直度综合测定仪使用说明
产品简介
YI、HBTCY-02型陶瓷砖平整度、直角度、边直度综合测定仪简介:
HBTCY-02型陶瓷砖平整度、直角度、边直度综合测定仪适用于测定各种墙面砖、地面砖尺寸及形状特性之仪器,其所测参数包括面砖的边直度、直角度、平整度(中心弯曲度、边弯曲度、翘曲度)等几项指标。本产品符合:GB/T3810.2 ,ISO?10545-2 《陶瓷砖-尺寸和表面质量的检验》的要求。
Brief introduction of hbtcy-02 ceramic tile flatness, right angle and edge straightness comprehensive tester:
Hbtcy-02 comprehensive measuring instrument for flatness, right angle and edge straightness of ceramic brick is suitable for measuring the size and shape characteristics of wall tiles and floor tiles. The parameters measured include the edge straightness, right angle, flatness (central bending, side bending, warping degree) and other indexes of the tiles. This product meets the requirements of GB / t3810.2, ISO? 10545-2 "ceramic tiles - Inspection of dimensions and surface quality".技术参数
二、HBTCY-02型陶瓷砖平整度、直角度、边直度综合测定仪技术参数:
1、测量精度:±0.1mm
2、测量范围: 300×300~800×800mm,300×300~1000×1000mm(用户选配)
3、标准板客户选购(选购件)?
4、根据用户要求可选用数显表。
5、外形尺寸:1200X1220X200mm
6、整机重量:95Kg
三、HBTCY-02型陶瓷砖平整度、直角度、边直度综合测定仪检测步骤:
每种类型的砖取10块整砖进行检测。
1、边直度与直角度的检测:
当砖放在仪器的三个支承销上时,使定位销靠近被测边,离测量边每个角的距离为5mm,边直度量表的测杆调整至被测边的中央处;直角度量表的测杆应在离测量边的个角5mm处。
将合适的标准板地置于仪器的测量位置上,调整量表的读数至合适的初始值。
取出标准板,将砖的正面恰当地放在仪器的定位销上,分别记录边中央处和离角5mm处的量表读数,如果是正方形砖,转动砖试样,得到4次测量值。每块砖都重复上述步骤,如果是长方形砖,分别测量长边和宽边的边直度和直角度。测量精度到0.1mm。
2、平整度的检测:
将相应的标准板地放在3个支承销上,每个支承销的中心到砖边的距离为10mm,中心弯曲度量表座杠杆触头应在砖中心位置,翘曲度量表座杠杆触头应在砖被测角离砖边10mm处,调节弯曲度和翘曲度量表的读数至合适的初始值。
取出标准板,将砖的釉面或合适的面朝下置于仪器上,分别记录每个量表的读数。如果是正方形砖,每块试样得到4个测量值,每块砖都重复上述步骤。测量精确到0.1mm。
Testing steps of hbtcy-02 ceramic tile flatness, squareness and edge straightness comprehensive tester:
10 whole bricks of each type are tested.
1. Detection of edge straightness and right angle:
When the brick is placed on the three supporting pins of the instrument, make the locating pin close to the side to be measured, and the distance from each corner of the measuring side is 5mm. The measuring rod of the side straight measuring meter shall be adjusted to the center of the side to be measured; the measuring rod of the right angle measuring meter shall be 5mm away from the measuring side.Put the appropriate standard plate on the measuring position of the instrument accurately, and adjust the reading of the gauge to the appropriate initial value.
Take out the standard plate, place the front face of the brick on the positioning pin of the instrument properly, record the meter readings at the center of the edge and 5mm away from the angle respectively, if it is a square brick, rotate the brick sample, and get the measured values for 4 times. Repeat the above steps for each brick. If it is a rectangular brick, measure the straightness and right angle of the long side and the wide side respectively. The measurement accuracy is 0.1 mm.
2. Flatness detection:
Put the corresponding standard plate on three supporting pins accurately, the distance between the center of each supporting pin and the brick edge is 10 mm, the lever contact of the center bending gauge seat should be in the center of the brick, and the lever contact of the warping gauge seat should be 10 mm away from the brick edge, and adjust the readings of the bending and warping gauges to the appropriate initial value.
Take out the standard board, put the glaze or appropriate face of the brick down on the instrument, and record the reading of each meter. If it is a square brick, four measurements are obtained for each sample, and the above steps are repeated for each brick. The measurement accuracy is 0.1 mm.
注意事项
四、HBTCY-02型陶瓷砖平整度、直角度、边直度综合测定仪注意事项:
1、放置试样或标准板时,应轻拿轻放,不要用力过大,以免影响检测结果。
2、仪器应安放在平稳且干净的基面上,保持仪器各部位的清洁,并不定期在仪器各部位表面抹擦少量机油以防锈蚀。
3、标准版另配。
主营产品:土工检测仪器,防水材料检测仪器,陶瓷砖检测仪器,水利水电粗粒土系列,沥青仪器检测仪器
Main products: geotechnical testing instrument, waterproof material testing instrument, ceramic brick testing instrument, water conservancy and hydropower coarse-grained soil series, asphalt testing instrument