简单介绍:Strong and Weak Cation-Exchange Columns for High-Resolution Separation of Proteins and MAbsNew! The Thermo Scientif

优质供应

详细内容

Strong and Weak Cation-Exchange Columns for High-Resolution Separation of Proteins and MAbs

New! The Thermo Scientific ProPac™ SCX column line has expanded to include the next generation ProPac SCX-20 column. This column provides unequalled high resolution of protein variants.

Please also see the Thermo Scientific MAbPac™ SCX-10 column, a strong cation-exchange column designed specifically for high-resolution, high-efficiency analysis of monoclonal antibodies (MAbs) and associated variants. This column is complimentary to the industry-leading ProPac WCX-10 column for monoclonal antibody variant analysis. The MAbPac SCX-10 offers an alternative selectivity and provides higher resolution and efficiency for variant analysis of most monoclonal antibody samples than the ProPac WCX-10 column.

ProPac SCX-10 and WCX-10 strong and weak cation-exchange columns are based on a nonporous core particle that results in high-efficiency peaks and high-resolution separations of protein variants. A hydrophilic layer prevents unwanted secondary interactions. A grafted cation-exchange surface provides pH-based selectivity control and fast mass transfer for high-efficiency separation and moderate capacity.

  • Characterization and quality control assessment of monoclonal antibodies and other proteins

  • Unequalled resolution

  • High-resolution separations with excellent sample recovery

  • Unmatched column-to-column and lot-to-lot reproducibility

  • Useful for characterization of related protein variants (e.g., deamidation and MAb lysine truncation variants)

  • Highly-efficient peaks with excellent sample recovery

  • Available in different dimensions and formats for flexibility in method development

The ProPac SCX-10 is a strong cation-exchange column with sulfonate functional groups, and the ProPac WCX-10 column has a carboxylate functional group. Both are based on 10 µm nonporous, polymeric beads and coated with a proprietary hydrophilic layer.

All ProPac columns are manufactured and tested under the strictest specifications, resulting in unmatched column-to-column and lot-to-lot reproducibility. These columns are available as lot-select packages containing three columns from a single lot or three columns from three different lots, to assist quality control scientists in method validation.

ProPac SCX-10 Strong Cation-Exchange Column for the High-Resolution Separation of Protein Isoforms  Specifications
Maximum operating pressure3000 psi (21 MPa)
Maximum operating temperature60 °C
Recommended operating temperature:<40 &deg;C
Typical operating conditionsUV detection at 1 mL/min
Recommended flow rate: 1 mL/min
phase compatibilitypH 2&ndash;12; 80% compatible with acetonitrile, acetone, methanol.
Compatible with nonionic and zwitterionic detergents.
Incompatible with cationic detergents.
Resin composition10-&micro;m-diameter core bead (55% cross-linked) grafted with a pellicular layer to which are attached the sulfonate functional groups.
Anion-exchange capacity< 100 &micro;g protein on-column, depending upon the protein
(4 &times; 250 mm analytical column)
Column constructionPEEK with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.

 

    ProPac WCX-10 Weak Cation-Exchange Column for the High-Resolution Separation of Protein Isoforms  Specifications
    Resin composition10-&micro;m-diameter core bead (55% cross-linked) grafted with a pellicular layer to which are attached the carboxylate functional groups.
    Anion-exchange capacity< 100 &micro;g protein on-column, depending upon the protein
    (4 &times; 250 mm analytical column)
    Column constructionPEEK with 10-32 threaded ferrule-style end fittings.
    All components are nonmetallic.
    Maximum operating pressure3000 psi (21 MPa)
    Maximum operating temperature60 &deg;C
    Recommended operating temperature:<40 &deg;C
    Typical operating conditionsUV detection at 1 mL/min
    Recommended flow rate: 1 mL/min
    phase compatibilitypH 2&ndash;12; 80% compatible with acetonitrile and acetone.
    Compatible with nonionic and zwitterionic detergents.
    Incompatible with cationic detergents.
     