SPECIFICATIONS | ||||
| ||||
Frequency | Range: | 0.100 000 MHz to 309.999 999 MHz | ||
| Resolution: | 1 Hz | ||
| Accuracy: | same as frequency standard | ||
| Control: | manual by 10-position dial; | ||
|
| remote by TTL-level parallel entry BCD or GPIB (optional) | ||
| ||||
Switching Time |
| (to within 0.1 radian at new frequency) | ||
| 100 MHz - 10 MHz digit: | 20 μseconds | ||
| 1 MHz digit: | 5 μseconds | ||
| 100 KHz - 1 Hz digit: | < 1 μsecond transient, 2 μsecond delay, phase-continuous | ||
| ||||
Output | Level: | +3 to +13 dBm (1V max, 50 W ) | ||
| Flatness: | ± 0.5 dB | ||
| Impedence: | 50 W | ||
| Control: | manual by front panel control; remote by analog voltage | ||
| ||||
Spurious |
| (at full power output, + 13 dBm) | ||
Outputs |
| Type 1 | Type 2 | |
| Discrete: | -65 dBc | -60 dBc | |
| Harmonics: | -30 dBc | -30 dBc | |
| Phase Noise: | -68 dBc | -63 dBc | |
|
| (0.5 Hz to 15 KHz) including the effects of internal standard | ||
| £ (1Hz): | 100 Hz/ -105 dBc, 1 KHz/ -115 dBc, 10 KHz/-123 dBc, 100 KHz/ -127 dBc | ||
| Noise Floor: | -135 dBc/Hz |
| |
| Optional Phase Rotation: | 0°, 90°, 180°, 270° in 90° steps | 0-360° in .225° steps | |
| ||||
Frequency | Internal: | OCXO | or | TCXO |
Standard |
| 3x10-9/day | 1x10-8/day | |
|
| ± 1x10-8/0-50° C | ± 1x10-6/0-50° C | |
|
| 1x10-6/year | 2x10-6/year | |
| External Drive: | 10 MHz, 0.4 Vrms into 50 W ; 5 MHz, 0.5 Vrms into 50 W | ||
| Aux. Output: | 10.000 MHz, 0.4 Vrms into 50 W | ||
|
| (Note: internal or external standard required for operation) | ||
| ||||
General | Operating Ambient: | 0-55° C, 95% R.H. | ||
| Power: | 105 - 125V, 50 - 400 Hz, 40W (100, 220, 240V optional) | ||
| Dimensions: | 19 x 3.5 x 17.5 inches (relay rack or bench cabinet) | ||
| Weight: | 20 lbs. | ||
| ||||
|
|