hart multidr-op master communication module
mvi46-hart
the mvi46 hart multidr-op master communication module is an slc backplane-compatible module that allows slc processors to interface easily with hart compatible devices. devices commonly supporting the protocol include pressure, temperature, flow transmitters, as well as other similar instruments commonly found in the process (and other) industry.
hart® is a registered trademark of the hart communication foundation
features and benefits
the mvi46-hart master communication module allows rockwell automation slc i/o compatible processors to easily communicate with hart slave devices. the mvi46-hart module interfaces up to 15 devices on each hart channel with the rockwell automation slc processor. four channels on the module support master protocol commands to interface with slave devices on their own networks. each port is individually configurable. data is exchanged between the hart network and the rockwell automation slc processor backplane using the internal database contained in the module and direct control by the controller"s ladder logic and pre-defined data ob-jects (5000 registers maximum).
the mvi46-hart module is the perfect solution for industrial applications in chemical and refining operations, to gas and liquid distribution systems, and remote offshore monitoring stations are addressing virtually all aspects of control, data acquisition, and maintenance.
general specifications
- single slot – 1746 backplane compatible (local or extended i/o rack only. remote rack not supported)
- the module is recognized as an input/output module and has access to processor memory for data transfer between processor and module using m0/m1 files
- ladder logic is used for data transfer between module and processor
- configuration data obtained through user-defined ladder. sample ladder file included
hardware specifications
specification | desc-ription |
backplane current load | 800 ma @ 5v (from backplane) |
operating temperature | 0 to 60°c (32 to 140°f) |
storage temperature | –40 to 85°c (–40 to 185°f) |
shock | 30g operational, 50g non-operational |
relative humidity | 5 to 95% (non-condensing) |
vibration | 5 g from 10150 hz |
led indicators | module status, backplane transfer status, application status, serial activity and error led status |
debug/configuration port (cfg) | |
cfgport (cfg) | rj45 (db-9m with supplied cable) rs-232 only |
configuration connector | rj45 rs?232 connector (rj45 to db-9 cable shipped with unit) |
application ports | |
application serial port (prt1, prt2) (serial modules) | (2) rj45 rs-232/422/485 application ports |
applications
the hart protocol is supported by major instrument suppliers and the hart communication foundation (hcf).
today, hart is the most widely used digital communications protocol for instruments in the process control industry. more than 105 manufacturers support hart with a choice of more than 170 different field instruments.
functional specifications
- the mvi46-hart module supports the hart multidr-op implementation of the protocol. following are some general specifications for the module:
- built in accordance to the hart bell 202 frequency shift keying (fsk) standard to superimpose digital signals at a low level on top of the 4 – 20ma
- four independent hart master ports that are completely user-configurable
- supports up to 15 devices per port
- point-to-point (slave address 0) or multidr-op (slave address 1 to 15) modes supported
- supports 99 universal and common practice commands per port to control and monitor devices with integer, ieee754 floating-point and packed ascii character string data blocks
- burst mode can be used for faster up-date of data from a single slave
- supports an auto polling feature that will automatically collect data from each hart instrument on the channel and store the data in the module database
- communication ports can be configured as a secondary master (that is, handheld configuration device)
protocol supported: hart protocol uses the bell 202 standard frequency shift-keying (fsk) digital signal to communicate at 1200 baud, superimposed at a low level on the 4 to 20ma analog measurement signal.
supported function codes: hart universal commands set supported are 00-03, 06-09, and 11-22. hart common practice commands set supported are 33-83 and 105–110.
hart network communications: supports four master channels. each channel on the module is configured independently to emulate a hart master. burst mode can be used for faster up-date of data from a slave device.
command polling is also user-configurable, including disabled, continuous, on change of data (write only), and dynamically user or automatic enabled.
status: error codes returned by the hart protocol available on an individual command basis. in addition, a slave status list is maintained per active channel.
hardware specifications
specification | desc-ription |
backplane current load | 800 ma @ 5v (from backplane) |
operating temperature | 0 to 60°c (32 to 140°f) |
storage temperature | –40 to 85°c (–40 to 185°f) |
shock | 30g operational, 50g non-operational |
relative humidity | 5 to 95% (non-condensing) |
vibration | 5 g from 10150 hz |
led indicators | module status, backplane transfer status, application status, serial activity and error led status |
debug/configuration port (cfg) | |
cfg port (cfg) | rj45 (db-9m with supplied cable) rs-232 only |
configuration connector | rj45 rs?232 connector (rj45 to db-9 cable shipped with unit) |
application ports | |
application serial port (prt1, prt2) (serial modules) | (2) rj45 rs-232/422/485 application ports |
- led indicators- hart channel activity (green)
- hart interface- four (4) hart multi-dr-op channels- screw terminals for each channel
- 24vdc power- screw terminal for 24vdc- provides hart loop power
ordering information
part number | part desc-ription |
mvi46-hart | hart multidr-op master communication module |