产品展示
甲基异丁基酮检测管153
点击次数:188发布时间:2012/3/20 10:40:41
更新日期:2012/9/21 14:20:44
所 在 地:其它
产品型号:153
优质供应
详细内容
甲基异丁基酮检测管153
的详细介绍甲基异丁基酮检测管153
Methyl isobutyl ketone No.153
(CH3)CHCH2COCH3
Performance |
Measuring Range | 0.05 to 0.6% |
Number of Pump Strokes | 2 |
Correction Factor | 1 |
Sampling Time | 1.5 minutes per pumpstroke |
Detecting Limit | 0.001% (n=2) |
Color Change | Orange→Darkgreen |
Reaction Principle | (CH3)2CHCH2COCH3+ Cr6+ + H2SO4 → Cr3+ |
Coefficient ofVariation | 10% (for 0.05 to 0.2%), 5% (for 0.2 to 0.6 %) |
ShelfLife | 3 Years |
Correctionsfor temperature & humidity | Temperature correction is necessary |
Store the tubes at cool and darkplace. |
Possible coexisting substances and theirinterferences | (NOTE) |
Substance | Concentration | Interference | Change color by itself |
Sulfurdioxide | 500 ppm | Plus error | Discolorsgreen |
Hydrogensulfide | 500 ppm | Plus error | Discolors darkgeen |
Alcohols,Esters,Ketones | - | Plus error | Discolors greenishbrown |
Propane | 0.2% | Cannot measure | Produce dark greenfor whole layer |
Aromatic HCs | 500 ppm | Plus error | Discolors Greenishbrown |
Othersubstance measurable with this detector tube |
Substance | CorrectionFactor | PumpStroke | MeasuringRange |
Styrene | 1.5 | 1 | 0.075 to0.9% |
Calibration gasgeneration | Static gas dilutionmethod |
TLV-TWA | TLV-STEL | Explosive range |
50ppm | 75ppm | 1.2to 8% |