产品展示
乙醚检测管161L
点击次数:198发布时间:2012/3/20 11:19:21
更新日期:2014/4/30 16:30:15
所 在 地:其它
产品型号:161L
优质供应
详细内容
检测管161L Ethylether
的详细介绍检测管161L Ethylether
Ethylether No.161L
(C2H5)2O
Performance |
Measuring Range | 10 to 400 ppm | 400 to 1200ppm |
Number of PumpStrokes | 2 | 1 |
CorrectionFactor | 1 | 3 |
Sampling Time | 4 minutes per pumpstroke | |
Detecting Limit | 2 ppm (n=2) | |
Color Change | Yellow → Paleblue | |
Reaction Principle | (C2H5)2O+ Cr6+ + H2SO4 → Cr3+ | |
Coefficient ofVariation | 10% (for 10 to 100ppm), 5% (for 100 to 400 ppm) | |
ShelfLife | 2Years | |
Correctionsfor temperature & humidity | Temperature correction is necessary | |
Store the tubes at cool and darkplace. |
Possible coexisting substances and theirinterferences | (NOTE) |
Substance | Concentration | Interference | Change color by itself |
Alcohols | - | Plus error | Produce pale bluediscoloration |
Esters | - | Plus error | Produce pale bluediscoloration |
Ketones | - | Plus error | Produce pale bluediscoloration |
Othersubstance measurable with this detector tube |
Calibration gasgeneration | Diffusion tubemethod |
TLV-TWA | TLV-STEL | Explosive range |
400ppm | 500ppm | 1.9to 4 8% |