您的位置:易推广 > 电工电气 > 工控系统及装备 > 其他工控系统及装备 > 广州晋宇自动控制设备有限责任公司 > 产品展示 > rogerwell产品系列 > 网关 > modbus rtu 转EIB

产品展示

modbus rtu 转EIB

点击次数:60发布时间:2014/3/27 11:26:56

modbus rtu 转EIB

更新日期:2014/3/27 11:26:56

所 在 地:中国大陆

产品型号:

简单介绍:集成网关intesisbox把Modbus 从设备转成KNX控制系统,集成到Modbus RTU从站设备(冷水机组,楼宇,电表,暖气地板,热泵,PLC)到KNX控制系统转换

相关标签:

优质供应

详细内容

  modbus rtu 转EIB

集成网关intesisbox把Modbus 从设备转成KNX控制系统,集成到Modbus RTU从站设备(冷水机组,楼宇,电表,暖气地板,热泵,PLC)到KNX控制系统转换

IntesisBox acts as a Modbus RTU master device in its Modbus interface, reading/writing points of the Modbus slave device(s), and offering this point"s values through its KNX interface. IntesisBox acts in the KNX side as one more device of the KNX system. IntesisBox"s KNX EIB interface connects directly to the EIB bus and is opto-isolated from the rest of the internal electronics
The Modbus interface of IntesisBox reads continuously by polling the Modbus slave devices/registers configured. If a non response of the Modbus slave is detected, the corresponding virtual signal inside IntesisBox will be activated indicating communication error with the device. All the updated readings of the Modbus registers are maintained in IntesisBox memory for immediate interaction with KNX when needed.
Each Modbus register of the slave device is associated to a KNX group address. All the Modbus registers of the different slaves are accessible through KNX group addresses.
When a change in any Modbus register/slave occurs, a write telegram is sent to the KNX bus, to the associated KNX group address. This is configurable individually per point.
IntesisBox KNX series are configured using LinkBoxEIB, a software tool for windowsTM which is supplied along with the purchase of IntesisBox with no additional cost. With the standard installation of LinkBoxEIB, a Demo project for integration of Modbus slave devices is also installed, using this demo project makes the engineering needed for this integration easy and quick.

 

 

Modbus 设备类型         
 点数  100  500  3000 能定义的点数到Intesisbox中
 Modbus从站设备  254  254  254  的从站设备点数也可以定义到Intesisbox中
 虚拟信号  1 per device  1 per device  1 per device  每个Modbus从站设备的错误信号定义一个错误。所有的由KNX提供

 

Intesisbox有三个版本---KNX MOdbus RTU主设备有不同的能力对每个型号

 Version with capacity of 100 points and up to 254 slave devices. Ref. IBOX-KNX-MBRTU-100.
 Version with capacity of 500 points and up to 254 slave devices. Ref. IBOX-KNX-MBRTU-A.
 Version with capacity of 3000 points and up to 254 slave devices. Ref. IBOX-KNX-MBRTU-B.

联系我们

联系人:邹小姐

点击查看联系方式

企业档案

  • 会员类型:免费会员
  • 工商认证: 【已认证】
  • 最后认证时间:
  • 法人:
  • 注册号:
  • 企业类型:代理商
  • 注册资金:人民币万

script>
在线咨询

提交