Summaryexplanation of the test:
The Wako phopholipids C is an enzymatic colorimetric method using N-Ethyl-N-(2-hydroxy-3-sulfopropyl)-3,5-dimethoxyaniline (DAOS). This is reagent has high specificityis not interfered with ascorbic acidbilirubin in serum.
Principle of the method:
As shown in the chemical reactions below, Phospholipids in serum (lecithin, lysolecithinsphingomyelin) are hydrolyzed to free choline by phospholipase D. The liberated choline is subsequently oxidized to betaine by choline oxidase with the simultaneous production of hydrogen peroxide. The hydrogen peroxide which is produced quantitatively, oxidatively couples 4-aminoantipyrineDAOS to yield a chromogen with maximum absorption at λ=600nm
Reagents (For 120 tests)
(1) Buffer Good''s buffer (pH 7.5) 50 mmol / L 8 x 50 mL
(2) Color Reagent (when reconstituted) 8 x for 50 mL
Phospholipase D 0.47 U/mL
Choline Oxidase 2.0 U/mL
Peroxidase 4.2 U/mL
DAOS 0.77 mmol/L
4-Aminoantipyrine 0.24 mmol/L
Ascorbic acid oxidase 3.9 U/mL
(3) Standard Solution 2 x 10 mL
(Corresponding to 300 mg/dL of phospholipids contents)
Choline Chloride 54 mg/dL
WarningsPrecautions
For In Vitro Diagnostic Use
Not to be used internally in humans or animals
Do not mix or use the reagents from one test unit with those of another test unit which has a different lot number.
Do not use reagents pat the expiration date stated on each reagent container label.
Specimen Collection
Serum
Ascorbic acid. Bilirubinhemolysis do not affect the phospholipids measurement.
The Wako method measures the 3 kinds of phospholipids in serum (lectithin, lysolecithinsphingomyelin) but does not measure cephalin.
Materials required but not supplied
Test tubes
Pipettes
Water bath, capable of maintaining 37 degree C
Spectrophotometer or Colorimeter, capable of measuring absorbance at 600 nm.
Preparation of reagent
COLOR REAGENT SOLUTION
Dissolve the contents of one vial (for 50mL) of Color Reagent in one bottle (50 mL) of Buffer. This solution is stable for 1 week at 2-10 degree C.
Procedure
Sample (S) Standard (Std) Blank (Bl)
Pipette into a test tube
Sample Sample 0.02 mL Standard 0.02 mL - *1
COLOR REAGENTSOLUTION 3.0 mL 3.0 mL 3.0 mL
Mix incubate for 5 minutes at 37 degree Cmeasure the absorbance of SStd against Bl at 600 nm.
Absorbance (600nm) A S A Std Blank
*1: The omission of 0.02 mL of water does not significantly affect the absorbance measured.
*2: When measure with two wavelength: λ1/λ2 = 600/700 nm.
CAUTION
The color reaction finishes in about 3 minutesthe 5 minutes of incubation at 37 degree C is enough for the reaction. The extended incubation will cause the color deterioration. Please avoid keeping the test tube warm longer than 15 minutes. The color is stable for 1 hour in room temperature.
Results
(Calculation) A S: Absorbance of sample
Phospholipids (mg/dL) = (A S / A Std ) x 300 A Std: Absorbance of standard
Limitations of the procedure
The calibration curve is linear up to 1000 mg/dL of phospholipids content.
Expected Values
Serum: 145 - 257 mg/dL
Since expected values are affected by age, sex, diet, geographical locationother factors, each laboratory should establish it own expected values for this procedure.
Additional recommended products
Code No. 410-00101 Control Serum I (Normal) 10 x for 5 mL
Code No. 416-00201 Control Serum II (Abnormal) 10 x for 5 mL
Reference
Takayama M., Itoh S., Nagasaki T.Tanimizu I.: Clin. Chim. Acta. 79, 93-98 (1977)
++++++++++++++++++++++++++++++++++++++
如有更多其它试剂产品需求与查询,请及时接洽:info@express-cn.com 或在我公司查询主页客户留言处(http://www.express-cn.com/expressgb/lyb.htm)留下您的查询内容,我们即会在当天为您作出回复。
伊普瑞斯科技有限公司
info@express-cn.com
总机:
传真:
www.express-cn.com
① 凡本网注明"来源:易推广"的所有作品,版权均属于易推广,未经本网授权不得转载、摘编或利用其它方式使用。已获本网授权的作品,应在授权范围内
使用,并注明"来源:易推广"。违者本网将追究相关法律责任。② 本网凡注明"来源:xxx(非本网)"的作品,均转载自其它媒体,转载目的在于传递更多信息,并不代表本网赞同其观点和对其真实性负责,且不承担此 类作品侵权行为的直接责任及连带责任。如其他媒体、网站或个人从本网下载使用 ,必须保留本网注明的"稿件来源",并自负版权等法律责任。
③ 如涉及作品内容、版权等问题,请在作品发表之日起两周内与本网联系,否则视为放弃相关权利。
④易推广页面显示产品信息均由企业自主发布,信息内容真实性、准确性与合法性由相关企业负责,易推广对此不承担任何责任,如遇非法或侵权信息欢迎监督,请联系QQ:1273397930或者发邮件至:1273397930@qq.com,如有确实证件证明属实,本站将对其删除处理,谢谢!
⑤ 本信息由注册会员:伊普瑞斯科技有限公司发布并且负责版权等法律责任。
易推广客服微信