the 2100an and 2100n laboratory turbidimeter display in units of nephelos (0-67 000 nephelos), ebcs (european brewery convention, 0-2, 450 ebcs), % transmittance, absorbence or colour units (apha ptco method). in addition, two application specific calibrations may be specified by the analyst. the application specific mode uses the nephelometric optical system in the same manner as the ntu measurement mode. special method development and sample characterisation also can be accomplished using the signal output from any of the four detectors.
features/benefits:
key benefits of the 2100an/2100n turbidity meters:
both the 2100an and 2100n turbidity meters offer these important features:
features exclusive to 2100an turbidity meter wider turbidity measurement range - 0 to 10,000 ntus; 0 to 67,000 nephelos; and 0 to 2450 ebcs--with automatic range se-lection and decimal point placement in each mode.
measures absorbance, % transmittance or color - user can se-lect from one of four measurement modes: turbidity, absorbance, transmittance or platinum-cobalt color units.
interchangeable 455 nm color filter for apha pt-co color measurement - a flow-thru cell is recommended when measuring color.
user specified unit display - enables user to customize units as needed for specific applications.
independent detector monitoring - independent detector signal readouts enable special method development or sample characterization.
programmable signal averaging - stabilizes displayed value if large or irregular shaped particles cause measured value to fluctuate excessively. user adjustable to 15 seconds.
built-in printer - features a built-in 28 column thermal printer.
real-time clock - permits date and time recording for measurements and calibration records. information is included in the printer report and rs232 data output.
sample identification number - identifies sample by number and includes information in the printer report and rs232 data output.
flow-cell capability - instrument accommodates any of three convenient flow-cell systems for improved accuracy and convenience in the laboratory. 2100an software enables operator to program flow time, duration, and static or dynamic measurements.
recorder output - recorder output expands instrument recording capability. internal printer, external rs232 and recorder outputs send signals simultaneously.
specifications:
| 2100an | 2100n |
principle of operation | nephelometric signal (90? ratioed to transmitted, forward scattered and back scattered signals; or nephelometric signal at 90?only | nephelometric signal (90? ratioed to transmitted, forward scattered signals; or nephelometric signal at 90?only |
operating | manual or auto range se-lection | manual or auto range se-lection |
measurement modes | se-lect ntus, ebcs, nephelos, abs, %t, color | se-lect ntus, ebcs or nephelos |
ranges: | 2100an | 2100n |
ntu mode | ratio on: manual 0-0.999, 0-9.99, 0-99.9, 0-10,000; auto 0-10,000 | ratio on: manual 0-0.999, 0-9.99, 0-99.9, 0-4000; auto 0-4000 |
nephelo mode | ratio on: manual 0-9.99, 0-99.9 and 0-67,000; auto 0-67,000 | ratio on: manual 0-9.99, 0-99.9, 0-26,800; auto 0-26,800 |
ebc mode | ratio on: manual 0-0.999, 0-9.99, 0-99.9, 0-2,450; auto 0-2,450 | ratio on: manual 0-0.999, 0-9.99, 0-99.9, 0-980; auto 0-980 |
absorbance | manual: 0.0 abs to 0.999 abs, 0 abs to 2.00 abs | -- |
transmittance | range 0.0 to 200 %t | -- |
color | range: 0 to 500 cu | -- |
accuracy: | 2100an | 2100n |
turbidity | 2 % of reading ?0.01 ntu from 0 to1000 ntu | 2 % of reading ?0.01 ntu from 0 to1000 ntu |
color measurement* | 2 cu from 0-30 (calibrated at 15 cu) | -- |
abs* (photometric linearity) | 0.005 abs from 0-1 abs at 455 nm | -- |
%t* (photometric linearity) | 1.2 %t from 0 to 100 %t at 455 nm | -- |
* flow cell required to achieve cited specifications. | ||
| 2100an | 2100n |
resolution | 0.001 on lowest range | 0.001 on lowest range |
repeatability | 1% of reading or ?0.01 ntu, whichever is greater | 1% of reading or ?0.01 ntu, whichever is greater |
response time | 6.8 seconds with signal averaging off or 14 seconds with signal averaging on | 6.8 seconds with signal averaging off or 14 seconds with signal averaging on |
① 凡本网注明"来源:易推广"的所有作品,版权均属于易推广,未经本网授权不得转载、摘编或利用其它方式使用。已获本网授权的作品,应在授权范围内
使用,并注明"来源:易推广"。违者本网将追究相关法律责任。② 本网凡注明"来源:xxx(非本网)"的作品,均转载自其它媒体,转载目的在于传递更多信息,并不代表本网赞同其观点和对其真实性负责,且不承担此 类作品侵权行为的直接责任及连带责任。如其他媒体、网站或个人从本网下载使用 ,必须保留本网注明的"稿件来源",并自负版权等法律责任。
③ 如涉及作品内容、版权等问题,请在作品发表之日起两周内与本网联系,否则视为放弃相关权利。
④易推广页面显示产品信息均由企业自主发布,信息内容真实性、准确性与合法性由相关企业负责,易推广对此不承担任何责任,如遇非法或侵权信息欢迎监督,请联系QQ:1273397930或者发邮件至:1273397930@qq.com,如有确实证件证明属实,本站将对其删除处理,谢谢!
⑤ 本信息由注册会员:Shantou Keyi instrument & Equipment co.ltd发布并且负责版权等法律责任。
易推广客服微信