您的位置:首页 > 产品展厅 > 仪器仪表 > 流量仪表 > 其他分析仪器 > Atomic Absorption Spectrophotometer
features:
. phase difference corrected monochromator, provide optimized optical path for entire wavelength.
. built-in 6 lamp turret, with 2 lamps (operation lamp and preparation lamp) simultaneously lightening.
. equipped with innovative and unique deuterium background correction (patent pending) for entire wavelength range.
. combustion gas cooling burner head is innovated newly and is applying patent. this technique could reduce much heating balancing time at the burner head.
. high safety air-acetylene flame facilitates 35 common elements analyzed at low operation cost.
. genius database system allows you to access index and abstracts of large amount of chinese and english literature.
complete automation on
. alignment and fine adjustment in hollow cathode lamp position.
. wavelength scan control and peak search and slit width se-lection.
. optimization of photomultiplier gain.
. energy balance between deuterium lamp and hollow cathode lamp.
. flame ignition (on/ off) as well as acetylene-o2 gas flow rate setting to optimize combustion ratio.
. optimization of analytical conditions for se-lected element simply by a mouse-click while six elements can downloaded simultaneously.
high safety
. fully automated gas control and integrated safety check yield the safest flame aa system available today.
. incorporated with air pressure sensor, acetylene gas flow will be cut in case of accident.
. combination of safety-designed burner head, special drainage system and pressurized valve control spray chamber.
. with presence of high pressure gas leakage check, it ensures automatic disconnection of gas lines in case of acetylene build up accidentally.
specifications
photometry: single-beam monochromator with grating of 1,800 lines/mm
wavelength range: 190 ?? 900 nm
bandwidth: 0.2, 0.4, 0.7, 1.4 nm
wavelength accuracy: ≤±0.45 nm
wavelength repeatability: ≤ 0.2 nm
resolution: ≤ 0.3 nm
baseline stability: ≤ 0.005a / 30 min (cu)
characteristic mass: cu ≤ 0.05 μg / ml / 1%
detection limit: cu ≤ 0.008 μg / ml
background correction: d2 lamp for entire wavelength, with correction of 30 times background
Atomic Fluorescence Spectrometer
AFS-3100 〈br〉Fully-Automatic Double-channel Atomic Fluorescence Spectrometer〈br〉
Atomic Absorption Spectrophotometer
The Accusys 211 AAS is the next evolution of the highly successful Buck 210-VGP ,
Atomic Absorption Spectrophotometer
The 210VGP is shipped ready for use. All operating conditions are preloaded in the internal computer
① 凡本网注明"来源:易推广"的所有作品,版权均属于易推广,未经本网授权不得转载、摘编或利用其它方式使用。已获本网授权的作品,应在授权范围内
使用,并注明"来源:易推广"。违者本网将追究相关法律责任。② 本网凡注明"来源:xxx(非本网)"的作品,均转载自其它媒体,转载目的在于传递更多信息,并不代表本网赞同其观点和对其真实性负责,且不承担此 类作品侵权行为的直接责任及连带责任。如其他媒体、网站或个人从本网下载使用 ,必须保留本网注明的"稿件来源",并自负版权等法律责任。
③ 如涉及作品内容、版权等问题,请在作品发表之日起两周内与本网联系,否则视为放弃相关权利。
④易推广页面显示产品信息均由企业自主发布,信息内容真实性、准确性与合法性由相关企业负责,易推广对此不承担任何责任,如遇非法或侵权信息欢迎监督,请联系QQ:1273397930或者发邮件至:1273397930@qq.com,如有确实证件证明属实,本站将对其删除处理,谢谢!
⑤ 本信息由注册会员:Shantou Keyi instrument & Equipment co.ltd发布并且负责版权等法律责任。
易推广客服微信