请登录 免费注册

热搜:通用机械五金工具仪器仪表安防监控

频道
通用机械 电子元器件 行业设备 五金工具 电工电气 仪器仪表 安防监控 专用汽车 照明灯具 化工原料 涂料 塑胶 建筑原料 皮革 冶金
您最近阅读过的产品
产品展示

您的位置:首页 > 产品展厅 >  仪器仪表 >  流量仪表 >  合成电阻 >  The moorLDI2-BI 双波长激光多普勒血流仪 创面成像系统

The moorLDI2-BI 双波长激光多普勒血流仪 创面成像系统The moorLDI2-BI

The moorLDI2-BI 双波长激光多普勒血流仪 创面成像系统

  • 价 格: 电议
  • 型号:The moorLDI2-BI
  • 生 产 地:英国
  • 访问:199次
  • 发布日期:2009/11/2(更新日期:1900/1/1)

北京吉安得尔科技有限公司

  • 提示:如果您未采购满意的产品,请在网页头部搜索更优质的产品
产品展示

双波长监测组织血流。 产品参数: 详情请向Gene&I咨询。 保修期: 一年 产品简介: 双波长监测,同时监测两个层面组织血流。
  • 详细内容
  • 公司简介
通过双波长激光,对两个层面的创面血流量进行扫描、记录、分析。
    主要用于糖尿病足、周围血管疾病、烧伤、休克等微血管血流量相关疾病的科研、临床工作。
    扫描范围:5cm x 5cm up to 50cm x 50cm
    the moorldi2 laser doppler blood perfusion imagers use a near infra-red laser beam (785nm in the standard moorldi2-ir  imager) or a visible red 633nm laser beam (moorldi2-vr imager). in the moorldi2-2λ  dual wavelength system 633 and 830nm lasers are combined to allow simultaneous imaging with the two wavelengths.
    the imagers are able to map tissue blood flow over areas from 5cm x 5cm up to 50cm x 50cm with 256 x 256 pixel resolution; - each pixel being an actual measurement. at high scan rates, over 64,000 measurements are made in less than 5 minutes.
    the moorldi2 is suitable for a wide range of clinical and research investigations and measurement of blood flow in the microcirculation. the moorldi2  range features a ccd camera which produces a colour image of the scanned area, making the positioning and comparison of images easier. the moorldi2-hr? highest resolution version is available with resolution to 100 microns.
    利用激光多普勒技术判断烧伤创面的损伤程度、预后情况判断。
    临床实验证明:bi扫描发现血流灌注量丰富的创面14天之内就会愈合良好
    bi扫描发现灌注量中等的创面愈合期在14天-21天之间
    bi扫描发现灌注量很低的烧伤创面明确提示医生可能需要手术、愈合期在21天以上
    本结果经全球烧伤科临床医学专家验证准确
    专业软件帮助轻松分析监测结果!
    注:影响烧伤愈后的因素很多,请根据多种情况分析判断!
    introduction
    the moorldi2-bi (moorldi2 burns imager) uses the laser doppler technique to predict the healing potential (hp) of a burn wound.
    clinical trials have shown that burn wounds heal within 14 days where there is high ld blood flow, between days 14 and 21 with ‘medium’ blood flow, and take longer than 21 days where there is low ld blood flow (the latter usually indicating that surgery is required).
    with the introduction of moorldi2-bi  laser doppler imager different regions of a mixed depth burn can be mapped in a single image. a full resolution scan includes 65,536 individual laser doppler measurements and these are displayed alongside a corresponding ccd image, as a colour coded image.
    accuracy of moorldi2-bi
    since the development of the moorldi, a number of publications have shown the higher accuracy of ldi in burn depth assessment.
    niazi et al. (1993) first evaluated the technique of burn depth measurement using ldi. they found that the commonest error (in four out of 17 cases) was overestimation of burn depth by the clinician. in only two cases did they underestimate burn depth. by comparison, when they used ldi to measure burn depth this was correct in all cases (4 superficial dermal and 13 deep-dermal or sub-dermal burns).
    pape et al. (2001) published an audit of the use of ldi in the assessment of burn depth. they reported that the ldi allowed accurate assessment of burn depth in 97% of burns, compared with 73% for clinical observation alone. these findings were similar to those reported by monstrey et al. (2001, abstract) who reported ldi accuracy of 93.3–96.6% compared to 61–67% for clinical evaluation, when ldi scanning was performed at day 3 and day 5 post-burn, respectively.
    jeng et al. (2001) stated that use of the ldi enabled them to make earlier and more ob-jective determination of the need to excise and graft burns. in a separate study, pape and byrne (2001) presented evidence that the use of ldi avoided unnecessary surgery, resulting in a reduction of both costs and workload.
    in 2002 holland et al. also reported that the moorldi  was an accurate method for the prediction of burn wound healing in children (holland et al., 2002). this study involved 57 children with a mean age of 1 year and 10 months. the sensitivity and the specificity of the moorldi  were higher than clinical evaluation:
    sensitivity ldi – 0.90; clinical evaluation – 0.66.
    specificity ldi – 0.96; clinical evaluation – 0.71 (holland et al., 2002)
    equipment required
    the moorldi2-bi package includes the moorldi2-bi  scan head, scan controller, touch-screen panel pc, all mounted on a mobile clinical stand that can be used in the ward, operating theatre, consulting room or special laser room. full installation, clinical training and certification is included together with a premium service contract.
    summary
    the moorldi2-bi can help the burn surgeon by indicating the healing potential (hp) of burn wounds. the current clinical practice is to report burn depth. for example, some burn surgeons use the latarjet classification (first-degree, superficial second-degree, deep second-degree and third-degree). we have introduced the term healing potential (hp) when interpreting moorldi2-bi burn scan images because healing is the recordable outcome measure relevant to large areas of burn, whereas assessment of depth (using biopsy) is only available at discreet points.
    a multi-centre study was carried out using the moorldi2-bi  to analyse the ranges of blood flow that correlated with healing within 3 specified time-periods; by post-burn day 14, between post-burn day 14 and 21, and greater than 21 days.
    the hp categories are:
    hp 14: the wound has the potential to heal within 14 days of the burn injury
    hp 14-21: the wound has the potential to heal between 14 to 21 days post burn
    hp >21: the wound will take longer than 21 days to heal
    the actual healing time of the wound will, however, depend upon other factors that can prolong wound healing (e.g. wound infection or use of inotropes). thus, the moorldi2-bi can provide an indication of the potential of the wound to heal but the actual healing time is dependent upon other clinical, biological and environmental factors.
    use of the moorldi2-bi has been shown to avoid unnecessary surgery in patients with superficial dermal wounds and promote early surgery for deep dermal wounds.
    the moorldi2  laser doppler blood perfusion imagers use a near infra-red laser beam (785nm in the standard moorldi2-ir imager) or a visible red 633nm laser beam (moorldi2-vr  imager). in the moorldi2-2λ dual wavelength system 633 and 830nm lasers are combined to allow simultaneous imaging with the two wavelengths.
    the imagers are able to map tissue blood flow over areas from 5cm x 5cm up to 50cm x 50cm with 256 x 256 pixel resolution; - each pixel being an actual measurement. at high scan rates, over 64,000 measurements are made in less than 5 minutes.
    the moorldi2  is suitable for a wide range of clinical and research investigations and measurement of blood flow in the microcirculation. the moorldi2  range features a ccd camera which produces a colour image of the scanned area, making the positioning and comparison of images easier. the moorldi2-hr  highest resolution version is available with resolution to 100 microns.
 

北京吉安得尔科技有限公司是由满怀报国理想的优秀华人科学家及本土商业精英共同创建,地址位于中关村腹地国家留学归国人员创业园,70%员工拥有国际著名学府Phd 学位,并获得国家创业基金支持。我们满怀赤诚之心,致力于探索生命奥秘,以世界上最先进的技术提高祖国人民的生存质量。我公司的甲醛快速检测试剂盒产品是我公司首席科学家(现供职于美国南加州大学)在美国期间的研究成果(现已申报国家发明专利和美国专利)。不同于市场上所有的类似产品,我公司开发的产品是基于三维立体测试方法,使用更方便,结果更直观,灵敏度最佳。相信我们专业技术与您一流的销售能力结合,一定能使我们的合作取得双赢!

产品留言

公司同类产品

版权说明

凡本网注明"来源:易推广"的所有作品,版权均属于易推广,未经本网授权不得转载、摘编或利用其它方式使用。已获本网授权的作品,应在授权范围内

使用,并注明"来源:易推广"。违者本网将追究相关法律责任。

本网凡注明"来源:xxx(非本网)"的作品,均转载自其它媒体,转载目的在于传递更多信息,并不代表本网赞同其观点和对其真实性负责,且不承担此 类作品侵权行为的直接责任及连带责任。如其他媒体、网站或个人从本网下载使用 ,必须保留本网注明的"稿件来源",并自负版权等法律责任。

如涉及作品内容、版权等问题,请在作品发表之日起两周内与本网联系,否则视为放弃相关权利。

易推广页面显示产品信息均由企业自主发布,信息内容真实性、准确性与合法性由相关企业负责,易推广对此不承担任何责任,如遇非法或侵权信息欢迎监督,请联系QQ:1273397930或者发邮件至:1273397930@qq.com,如有确实证件证明属实,本站将对其删除处理,谢谢!

本信息由注册会员:北京吉安得尔科技有限公司发布并且负责版权等法律责任。

最新产品 - 今日最热门报道-分类浏览 - 每日产品
  • 易推广客服微信