您的位置:首页 > 产品展厅 > 大功率可编程电子负载(600W~50kW)
参数 | IT8515C | IT8516C | IT8518C | |
额定值 ( 0 °C~40 °C) | 电压 | 0~120V | 0~120V | 0~60V |
电流 | 0~240A | 0~240A | 0~240A | |
功率 | 1800W | 2400W | 5000W | |
负载精度 | 范围 | 精度 | 解析度 | |
0~18V | ±(0.05%+0.02%FS) | 1mV | ||
0~120/60V | ±(0.05%+0.025%FS) | 10mV | ||
0~24A | ±(0.1%+0.1%FS) | 1mA | ||
0~240A | ±(0.2%+0.15%FS) | 10mA | ||
定电压模式 | 0.1~18V | ±(0.05%+0.02%FS) | 1mV | |
0.1~120/60V | ±(0.05%+0.025%FS) | 10mV | ||
定电流模式 | 0~24A | ±(0.1%+0.1%FS) | 1mA | |
0~240A | ±(0.2%+0.15%FS) | 10mA | ||
定电阻模式 (当输入电压和电流值≥10%0.1~10Ω | ±(1%+0.3%FS) | 0.001Ω | ||
10~99Ω | ±(1%+0.3%FS) | 0.01Ω | ||
100~999Ω | ±(1%+0.3%FS) | 0.1Ω | ||
1K~4KΩ | ±(1%+0.8%FS) | 1Ω | ||
(当输入电压和电流值≥10%0~100W | ±(1%+0.1%FS) | 1mW | ||
100W~1.8kW/2.4kW/5kW | ±(1%+0.1%FS) | 100mW | ||
电流量测值 | 0~24A | ±(0.1%+0.1%FS) | 1mA | |
0~240A | ±(0.2%+0.15%FS) | 10mA | ||
电压量测值 | 0~18V | ±(0.02%+0.02%FS) | 1mV | |
0~120/60V | ±(0.02%+0.025%FS) | 10mV | ||
(当输入电压和电流值≥10%0~100W | ±(1%+0.1%FS) | 1mW | ||
100W~1.8kW/2.4kW/5kW | ±(1%+0.1%FS) | 100mW | ||
电池测试功能 | Input=0.8~120/60V Max measurement capacity= 999A/H Resolution=10mA Timer range=1~60000sec | |||
动态测试模式 | Range o Frequency 0.1Hz~1kHz Frequency error rate<0.5% | |||
尺寸 (mm<SPANSTYLE=”FONT-FAMILY: Arial?>) | 444mmW×180mH×539mmD | 444mmW×357mH×539mmD | ||
重量 (净重) | 25 kg | 55kg |
① 凡本网注明"来源:易推广"的所有作品,版权均属于易推广,未经本网授权不得转载、摘编或利用其它方式使用。已获本网授权的作品,应在授权范围内
使用,并注明"来源:易推广"。违者本网将追究相关法律责任。② 本网凡注明"来源:xxx(非本网)"的作品,均转载自其它媒体,转载目的在于传递更多信息,并不代表本网赞同其观点和对其真实性负责,且不承担此 类作品侵权行为的直接责任及连带责任。如其他媒体、网站或个人从本网下载使用 ,必须保留本网注明的"稿件来源",并自负版权等法律责任。
③ 如涉及作品内容、版权等问题,请在作品发表之日起两周内与本网联系,否则视为放弃相关权利。
④易推广页面显示产品信息均由企业自主发布,信息内容真实性、准确性与合法性由相关企业负责,易推广对此不承担任何责任,如遇非法或侵权信息欢迎监督,请联系QQ:1273397930或者发邮件至:1273397930@qq.com,如有确实证件证明属实,本站将对其删除处理,谢谢!
⑤ 本信息由注册会员:深圳市联创通科技有限公司发布并且负责版权等法律责任。
易推广客服微信