Specifications
Safe Overload | 120%RC |
Rated Output | 1.5mV/V±1% (1MPa) |
2.0mV/V±1% (2MPa to 50MPa) | |
Nonlinearity | 0.5%RO (1MPa) |
0.3%RO (2MPa to 50MPa) | |
Hysteresis | 0.5%RO (1MPa) |
0.3%RO (2MPa to 50MPa) | |
Repeatability | 0.3%RO (1MPa) |
0.2%RO (2MPa to50MPa) | |
Excitation Voltage | 10V (or less) |
Safe Excitation Voltage | 15V |
Input Rsistance | 350Ω |
Output Rsistance | 350Ω |
Compensated Temp.Range | -10 to 60℃ |
Safe Temp.Range | -20 to 80℃ |
Temp.Effect on Zero | 0.03%RO/℃ (1MPa) |
0.02%RO/℃ (2MPa to 50MPa) | |
Temp.Effect on Output | 0.05%/℃ |
Cable | Φ6mm-4wire shielded cable, length : 0.3m |
Connector | Jack / PRC03-32A10-7F |
Attached cable | L-A-5 (Refer to transducer connections) |