Repeatability: Coefficient of Variation (COV = Standard Deviation/Average) of ±2% or better (±5% for sample ranges of less than 2 ppm)
Linearity: Correlation coefficient (R2) of 0.995 or better
Drift: 0% Baseline drift with standard automatic zeroing prior to each analysis
Response time: TC: 3 minutes TOC: 4 minutes
Detector: High-sensitivity non-dispersive infrared detector Environmental Conditions
Sample Conditions
Pressure: 0-5 psig (0.35 bar)
Sample Flow: 50-1000 cc/minute to the overflow cup
Suspended solids size: 200 microns or less (50 micron recommended)
Suspended solids conc.: 1000 mg/liter or less
Dissolved Solids conc.: 0 to 3% standard, higher with dilution Utility Requirements
Power: 115 VAC/60 Hz/5A, 220 VAC/50 Hz/3A, 100 VAC/60 Hz/5A
Instrument Air: Instrument grade at 60 psig minimum, 3 CFM (intermittent)
For optional vortex chiller: 80 psig, 25 SCFM (5.5 bar, 706 CLM)
For optional Z-Purge: 60 psig, 6 SCFM (4 bar, 170 CLM)
Carrier Gas: Purified nitrogen, CO2-free air or oxygen at 120 cc/minute, min. 50 psig (3.5 bar)
Water: De-ionized or distilled (approx. 2 gallons/week)
Acid (for 6800 TOC only): 1.0 N H2SO4 if sample pH 〈 7 (approx. 1 gallon/ week) 2.0 N H2SO4 if sample pH > 7 (approx. 1 gallon/ week)
Signal Outputs
Standard: 0-10 VDC, 4-20 mA isolated
Alarms: Single- or dual-level, 100% adjustable (rated at 1 amp at 115VAC 50/60 Hz)
Options
Fail Safe Alarm Package: Indicates loss of power, sample, reagent, carrier gas, and oven temperature
Sample Preparation: Low-Maintenance Filtration system; Sample Conditioning System erless Recorder
Dual stream package: Built-in option. Includes two sample overflow cups, automatic rinse between samples, and 4-20mA and alarm outputs for each stream
Automatic Calibration: Available upon request
Enclosures: NEMA 4X Enclosure
Coolers and Purges: Purge with Vortex Chiller; Z-Purge with Vortex Chiller
Heater: For use with the NEMA 4X enclosure above.
Data Communications: Remote Start ; Stripchart Recorder; Electronic Data Recorder; Paperless recorder
Other Accessories: Platinum Catalyst Kit; Carrier Gas Generator; Carrier Gas Module
Dimensions and Weight
Electronics Module: 72" H 28" W 13.55" D (183cm 71cm 35cm)
Reaction Module: 72" H 28" W 13.55" D (183cm 71cm 35cm)
Total Net Weight: Approx. 200 lbs. (91 kg) gross shipping weight
Ionics 6800 On-line TOC/TC Analyzer Specifications
上海日置测试仪器有限公司是一家致力于水质分析和监测仪器、仪表的销售,提供相关技术支持和维修服务的专业性科学仪器公司,是美国Ionics/Sievers公司在中国地区的代理。
上海日置坚持以提高用户营运成效为宗旨,以先进的水质监测和分析系统服务于半导体、制药、环保行业等的纯水、回用水、地表水、废水处理和监测。
我公司提供的仪器能对总有机碳(TOC),硼(Boron),溶解氧(DO),硅酸根(Silica),浊度(Turbidity),余氯(Chorine),化学耗氧量(COD),超净车间空气中的氨气(Ammonia),水或空气中的颗粒数(Particle Counter)等指标进行连续准确的实时监测。公司同时还提供多种分析仪器的校正标样、试剂和耗材。
上海日置安排其技术支持和售后服务工程师经常参加由生产厂家举办的技术服务培训,确保在提供客户所需产品的同时,保证高质量的售后服务。
上海日置和所有的客户建立密切的合作伙伴关系。我们相信,客户的成功要比我们在业绩上所取得的成就更能彰显科学分析仪器的广阔市场前景!
网站地址:www.shanghairizhi.com
网络实名:TOC