The AA-10R series are compact, versatile, fully automatic polarimeters, suitable for measuring the rotation of optically active compounds across numerous samples throughout a vast range of laboratory applications.
With cast aluminium base and solid panels, the AA-10R series polarimeters are extremely robust. Although the most compact polarimeter in the market, the sample compartment accepts standard size tubes up to 200mm path length.
Both models have 3 keys: an on/off switch, a zero button and a "print" key, making operating the instrument easy.
Samples up to OD 1.5 (i.e a sample which absorbs less than 95% of the incident light beam) can be measured accurately by the use of a halogen lamp in conjunction with a very narrow band interference filter (standard wavelength 589.44nm). This ensures that readings are not biased due to sample colour.
A warning is given by the digital display if the OD 1.5 absorption tolerance is exceeded. Better results can generally be obtained with highly absorbing samples if the tube length is reduced.
The AA-10R series is available in two versions:
To use the AA-10R polarimeter, simply press the set zero button once at the start of work; pour your solution into a sample tube, place the tube into the instrument and, in a few seconds, the result is shown on the digital LED display.
Versatility comes from choosing different tubes for different applications, for example, up to 4 samples per minute can be measured using a flow cell and either a funnel or an auto-sampler.
The unique operating principle of the AA-10R polarimeter, patented by Optical Activity Limited in the 1970"s, allows measurement of flowing samples and tolerates some turbulence, small bubbles or suspended solids, which would completely upset other polarimeters
specification | aa-10r angular scale model | aa-10r sugar scale model |
scale | degrees | iss degrees |
range | ±90° | ±199°z |
accuracy | ± 0.01° | ± 0.02°z |
wavelength | 589.44nm | |
light source | halogen filament lamp approximate life 2000 hours | |
outputs | digital led display, plus rs232 25-way output socket | |
reading time | <8 seconds <8 seconds | |
sample compartment | accepts standard polarimeter tubes with 30mm circular ends. maximum path length 200mm, bores 8mm down to 1.5mm | |
controls | power on/off, set zero button, print keydual wavelength model has a wavelength se-lection knob | |
special features | warning if sample transmittance is less than the 3% (ie, od 1.5) required for accurate measurement | |
power requirements | ac line voltage 230v ± 20% or 115v ± 20% 45hz to 65hz, 10 watts | |
emc and low voltage directives | ce marked complies with the following regulation 89/336/eec as amended by 91/263/eec and 92/31/eec electromagnetic compatibility directive (emc) and 93/68/eec low voltage directive | |
size (l x d x h) | 460 x 220 x 90 mm | |
weight | 8.5kg (gross weight packed - between 12 and 18kg) |
http://www.opticalactivity.com/aa-10.htm
北京东方银华贸易商行是新创建的科学仪器经销公司,精心为国内市场选择和进口国际名牌分析和实验室仪器.在国内国外享有声誉.
独家代理和经销的公司和产品有:
1 美国Reichert公司分析仪器部((前徕卡显微系统公司分析仪器部))授权东方银华商行为中国唯一的经销商。
2 2004年开始成为英国OPTICAL ACTIVITY有限公司和英国INDEX仪器有限公司的中国独家代理。主要为中国的分析实验室,特别是为制糖,饮料,番茄加工,香精香料和制药行业的实验室和质检机构提进口质量上乘价格适中的英国自动旋光仪,自动糖度旋光仪,葡聚糖和蔗糖分析系统,自动折光仪,糖品色值/混浊度测定仪等专业品牌分析仪器。
3 美国QUANTEK气体分析仪,适合现代包装检测
4 意大利LABOSCIENTIFICA的番茄色差仪
5 德国NAGY高精度水分活度快速测定仪
6 美国ATM 公司工业用筛网和精密筛振仪
7 美国PSI公司的冰点仪和渗透压仪等。
欢迎各界朋友前来联系业务,北京东方银华贸易商行愿意以最优的价格和服务为中国用户服务.
① 凡本网注明"来源:易推广"的所有作品,版权均属于易推广,未经本网授权不得转载、摘编或利用其它方式使用。已获本网授权的作品,应在授权范围内
使用,并注明"来源:易推广"。违者本网将追究相关法律责任。② 本网凡注明"来源:xxx(非本网)"的作品,均转载自其它媒体,转载目的在于传递更多信息,并不代表本网赞同其观点和对其真实性负责,且不承担此 类作品侵权行为的直接责任及连带责任。如其他媒体、网站或个人从本网下载使用 ,必须保留本网注明的"稿件来源",并自负版权等法律责任。
③ 如涉及作品内容、版权等问题,请在作品发表之日起两周内与本网联系,否则视为放弃相关权利。
④易推广页面显示产品信息均由企业自主发布,信息内容真实性、准确性与合法性由相关企业负责,易推广对此不承担任何责任,如遇非法或侵权信息欢迎监督,请联系QQ:1273397930或者发邮件至:1273397930@qq.com,如有确实证件证明属实,本站将对其删除处理,谢谢!
⑤ 本信息由注册会员:北京东方银华贸易商行(Silverado Trading Company)发布并且负责版权等法律责任。
易推广客服微信